The cooling tower is a cooling device, which makes the hot water in the tower be cooled mainly by the evaporative cooling of water. In order to make full use of water resources, reduce the load of urban tap water supply network, and reduce the operating cost, cooling water is treated by cooling tower and recycled.
“Fill” is a medium that used in cooling towers to increase the surface area available for the water.
In a cooling tower, the really important actually is cooling tower fill. Fill is a plastic sheet used in cooling towers to build the more surface region of the tower. If we want to expanded surface, we need to take considers into making more contact about water and fills, so that water will have more surface area in the cooling tower fill.
Cooling tower fills make hot water have much more surface area with sheet and air and the medium of tremendously extended film fill, so that hot water is cooled quickly.
After be cooled the water is flow in a water container from which it is pumped again to cooling other hot water, and the warm air leaving the fill and releasing from the above of the cooling towers ,and like this Continuously cooling air from bottom and release warm air from above to keep cooling tower cooling hot water continuously, to reduce the load of urban tap water supply network, and reduce the operating cost, So that we could make full use of water resources.
Filler is the most important part of the cooling tower, and its efficiency depends on the extent to which the cooling water and air are fully in contact with the filler. Filler temperature 50 °C ~ 68 °C, anti-aging, excellent performance, anti-ultraviolet, long life.
Cooling tower fill should be made to have more contact about water and fills , and longest time as possible. Fill allows the water to form thin flowing sheets to expose as much water surface area as possible to the interacting flow.
| Type | VF610-LC |
| Material | PP/PVC |
| Width | 305mm |
| Length | as your request |
| Thickness | from 0.28mm to 0.38mm |
| Sheet Space | 19mm |
| Application |


The VF610-LC model uses a published sheet spacing of 19 mm. This dimension is important when comparing replacement fill media with the existing tower configuration. Sheet spacing should be evaluated together with the fill geometry, water conditions and airflow requirements rather than treated as an independent performance guarantee.
We offer VF610-LC cooling tower fill in PVC and PP options. Material selection should consider the expected water temperature, circulating water chemistry, operating environment and required service conditions. Confirm the applicable product grade and operating limits before placing an order.
VF610-LC fill length can be supplied according to order requirements. Customers should provide the required dimensions and any restrictions imposed by the cooling tower support system to confirm the appropriate replacement configuration.
VF610-LC is intended for compatible counterflow cooling tower arrangements. It can be considered for replacement projects when the sheet profile, pack size, material and installation support requirements match the existing equipment.
Before ordering VF610-LC replacement fill, we recommend checking the following details against the existing installation:
Fill width: Confirm compatibility with the published 305 mm sheet width.
Required length: Provide the existing fill dimensions or replacement drawings.
Sheet spacing: Check whether the 19 mm configuration matches the intended tower design.
Sheet thickness: Select the required option within the available 0.28–0.38 mm range.
Material: Specify PVC or PP according to project requirements.
Support and installation: Verify support spacing, pack orientation and available installation space.
If your existing fill model is unknown, provide photographs, sample dimensions and tower identification information so that the replacement requirements can be reviewed.
VF610-LC is offered for compatible counterflow cooling towers used in industrial cooling and HVAC applications. The suitability of this model depends on the tower's design and operating conditions.
Replacement of compatible counterflow fill packs.
Cooling tower maintenance and refurbishment projects.
Industrial cooling tower equipment procurement.
HVAC cooling tower replacement requirements.
Long Zhuo supports customers purchasing VF610-LC cooling tower fill for equipment projects, service work and replacement orders. We can review required dimensions, available material options, product configurations and bulk purchasing quantities.
For an accurate VF610-LC quotation, please send:
VF610-LC model reference or existing fill photographs.
Required sheet thickness and material.
Length, width and installed pack dimensions.
Cooling tower type and operating water temperature.
Required quantity and delivery destination.
Any relevant installation drawing or existing sample.
Long Zhuo products mainly include Cooling Tower Accessories (such as Cooling Tower Fill, Drift Eliminator, Mist Eliminator, Spray Nozzle etc.) Water Treatment Media (such as Tube Settler, MBBR Media, Bio Ball Media, Diffusion Aerator etc.) and Water Tank (such as GRP Water Tank, Galvanized Steel Water Tank, Stainless Steel Water Tank). All of the products support OEM.
If you need, click here:
sales@coolingtowerinfill.com
admin@longzhuochn.com